DELL EMC D-VXB-DY-A-24 Practice Exams
Last updated on Oct 22,2026- Exam Code: D-VXB-DY-A-24
- Exam Name: Dell VxBlock Deploy Achievement
- Certification Provider: DELL EMC
- Latest update: Oct 22,2026
You are testing a recently expanded VxBlock 1000.
How can you verify that the hosts can communicate with XtremIO?
- A . Deactivate the storage controller
- B . Failover the Data Mover
- C . Reboot the BBU
- D . Power off a ToR switch
D
Explanation:
To verify that the hosts can communicate with XtremIO in a VxBlock 1000, you can power off a ToR (Top of Rack) switch. This test helps ensure that network redundancy and failover mechanisms are working correctly, confirming that communication is maintained through alternative paths.
Reference: Dell EMC VxBlock 1000 test plan guidelines.
Network redundancy testing procedures.
Which required NSX component abstracts the physical network and provides access-level switching in the hypervisor?
- A . Edge Services Gateway
- B . vSphere Distributed Switch
- C . Distributed Logical Router
- D . vSphere Standard Switch
C
Explanation:
The Distributed Logical Router (DLR) is the NSX component that abstracts the physical network and provides access-level switching in the hypervisor. The DLR enables routing between different virtual networks and operates at the hypervisor level, providing high-performance distributed routing capabilities.
Reference: VMware NSX documentation.
Technical resources on NSX architecture and components.
A customer has a physical server connected to an ACI fabric. The server was recently moved to a different leaf switch within the ACI fabric. The IP address of this server was also changed but is still part of its original EPG.
What is a consideration once the correct port configuration is pushed from the APIC?
- A . The host must be removed, and the connections need to be re-assigned.
- B . No configuration changes are required on the ACI fabric.
- C . The switch must be moved with the machine to the new site.
- D . The contract needs to be updated to reflect the new IP address.
B
Explanation:
Understand ACI Fabric: Cisco’s Application Centric Infrastructure (ACI) fabric is designed to be dynamic and flexible, allowing for seamless movement of servers and changes within the fabric1. Recognize EPG Membership: When a server that is part of an Endpoint Group (EPG) is moved to a different leaf switch and its IP address is changed, the EPG membership remains consistent as long as the server’s identity is recognized within the ACI fabric1.
Identify Port Configuration: The correct port configuration is pushed from the Application Policy Infrastructure Controller (APIC), which updates the fabric about the server’s new location and IP address1.
Confirm No Further Changes Needed: Once the APIC has the updated information, no additional configuration changes are required on the ACI fabric. The fabric automatically adjusts to the server’s new location and IP address within the same EPG1.
Which base feature of Isilon OneFS is enabled during the CPSD Logical Build process?
- A . SynclQ
- B . SMARTDEDUP
- C . SMARTCONNECT
- D . SnapshotIQ
C
Explanation:
Review Isilon OneFS Features: Isilon OneFS is a storage platform that offers a range of features, some of which require licensing1.
Identify Base Feature: Among the base features of Isilon OneFS, SMARTCONNECT is typically enabled during the CPSD Logical Build process1.
Understand SMARTCONNECT: SMARTCONNECT is designed to optimize resource utilization and performance by directing client requests to the most suitable node within the cluster1.
Reference Official Documentation: The Official Dell VxBlock Deploy Achievement document would list SMARTCONNECT as the base feature enabled during the CPSD Logical Build process, aligning with industry standards for data protection1.
A customer is using Cisco UCS 6332-16UP 40-Port Fl. They have 16 ports dedicated for FC traffic. The customer needs to increase the number of FC ports.
What is a consideration?
- A . Unused server ports can be converted to FC ports
- B . Maximum number of supported FC ports is 32
- C . Unused FCoE ports can be converted to FC ports
- D . Maximum number of supported FC ports is 16
A
Explanation:
In the Cisco UCS 6332-16UP 40-Port Fabric Interconnect, unused server ports can be converted to FC (Fibre Channel) ports. This flexibility allows customers to reconfigure ports based on their specific needs, increasing the number of available FC ports when additional FC connectivity is required.
Reference: Cisco UCS Fabric Interconnect configuration guides.
Cisco UCS 6300 Series Fabric Interconnect data sheets and documentation.
A user cannot connect to Management switch 3172TQ. During troubleshooting it was discovered that the wrong IP was used in the SSH client.
What IP address should be used to establish the SSH connection to the Management switch?
- A . 192.168.1.1
- B . 10.10.10.2
- C . 192.168.1.2
- D . 10.10.10.1
D
Explanation:
To establish an SSH connection to the Management switch 3172TQ, the IP address 10.10.10.1 should be used. This is the default IP address for the management interface on the switch, allowing for administrative access and configuration.
Reference: Dell EMC VxBlock system documentation.
Network administration guides for switch management and access.
What is encapsulated by a VxLAN?
- A . Layer 2 Ethernet frames in Layer 3 UDP-IP packets
- B . Layer 3 Ethernet frames in Layer 2 UDP-IP packets
- C . Layer 3 UDP-IP packets in Layer 2 Ethernet frames
- D . Layer 2 UDP-IP packets in Layer 3 Ethernet frames
A
Explanation:
Understand VxLAN: VxLAN, or Virtual Extensible LAN, is a network virtualization technology that encapsulates Layer 2 Ethernet frames within Layer 3 UDP packets1.
Identify Encapsulation Process: This encapsulation allows for the creation of a virtualized Layer 2 network over an existing Layer 3 infrastructure, enabling greater scalability and flexibility in network design1.
Recognize VxLAN Functionality: By encapsulating Layer 2 frames in UDP packets, VxLAN extends Layer 2 networks over Layer 3 networks, which is particularly useful in cloud computing and data center environments1.
Reference Official Documentation: The Official Dell VxBlock Deploy Achievement document would align with this understanding of VxLAN, highlighting its role in network virtualization and the encapsulation process1.
What is the maximum number of X-Bricks that can be installed on a single XtremlO X2 array?
- A . 8
- B . 6
- C . 2
- D . 4
A
Explanation:
Review XtremIO X2 Specifications: The XtremIO X2 storage array is designed to support a scale-out architecture, allowing for the addition of multiple X-Bricks to increase capacity and performance1. Identify Maximum X-Bricks: According to the specifications, a single XtremIO X2 array can be scaled out to a maximum of 8 X-Bricks1.
Understand Capacity Expansion: This scale-out capability enables the XtremIO X2 array to reach a large physical capacity, accommodating the storage needs of various applications and workloads1. Reference Official Documentation: The Official Dell VxBlock Deploy Achievement document would align with this information, providing details on the scalability options for the XtremIO X2 storage array1.
What is the recommended source to download a Test Plan for a specific VxBlock model?
- A . https://cpsdocs.dellemc.com/
- B . https://vce.flexnetoperations.com
- C . DellEMC Support
- D . SolVe Online
D
Explanation:
Access SolVe Online: SolVe Online is Dell EMC’s online tool that provides step-by-step procedures and support for various products, including VxBlock Systems1.
Navigate to VxBlock Section: Within SolVe Online, navigate to the section dedicated to VxBlock Systems to find resources specific to these models1.
Locate Test Plan: Look for the Test Plan associated with the specific VxBlock model you are working with. The Test Plan is typically available in the form of downloadable documents or guides1. Download Test Plan: Once located, download the Test Plan for the specific VxBlock model to use as a reference for deployment or troubleshooting1.
Verify with Documentation: Ensure that the downloaded Test Plan matches the model and version of the VxBlock System you are using by cross-referencing with the official documentation1.
A System Engineer is working on an implementation of the VxBlock 1000.
What is a required task in the final implementation step during the Deployment Phase?
- A . Verify system physical configuration against LCS
- B . Execute the agreed-upon test plan
- C . Configure Cisco Smart Call Home
- D . Connect to individual Element Managers
B
Explanation:
Review Deployment Phase Requirements: The final implementation step during the Deployment Phase of a VxBlock 1000 involves ensuring that the system is functioning as expected1.
Identify Required Task: A critical task in this step is to execute the test plan that was agreed upon during the planning phase1.
Understand the Importance of Test Plan Execution: Executing the test plan is essential to validate that all components of the VxBlock 1000 are working correctly and that the system meets the customer’s requirements1.
Reference Official Dell Documentation: The Official Dell VxBlock Deploy Achievement document outlines the importance of executing the test plan as a required task in the final implementation step during the Deployment Phase1.