DELL EMC D-PE-OE-23 Practice Exams
Last updated on Oct 23,2026- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Oct 23,2026
A Dell EMC PowerEdge 13G server is being controlled through a secure port by iDRAC8.
What login connection options are available on server using a secure port?
- A . DRM only
- B . RACADM CLI and DRM
- C . Web GUI and RACADM CLI
- D . Web GUI and SSH
A Dell EMC PowerEdge 13G server is being controlled through a secure port by iDRAC8.
What login connection options are available on server using a secure port?
- A . DRM only
- B . RACADM CLI and DRM
- C . Web GUI and RACADM CLI
- D . Web GUI and SSH
If a server does not have an OS installed which two can be used to start a SupportAssist collection? (Select 2)
- A . Front LCD
- B . System BIOS
- C . LifeCycle Controller
- D . iDRAC
- E . OMSA
What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?
- A . Ensures that the installed operating system is authentic
- B . Ensures that the server has a valid Service Tag number
- C . Ensures that no unauthorized BIOS or firmware codes are run
- D . Ensures that the server boots only when connected to a verified network
From PERC8 to PERC9, the maximum number of individual drives upon which a virtual disk can be created changed.
How did this value change?
- A . 8 to 32
- B . 16 to 64
- C . 16 to 32
- D . 8 to 16
From PERC8 to PERC9, the maximum number of individual drives upon which a virtual disk can be created changed.
How did this value change?
- A . 8 to 32
- B . 16 to 64
- C . 16 to 32
- D . 8 to 16
A technician replaces a faulty system board on a server. In addition to powering on the system, what step must the technician take to install the correct service tag?
- A . Type asset <asset tag> to change the asset tag
- B . Login in to the iDRAC
- C . Press F11 to start the Boot Manager
- D . When prompted by Easy Restore, press Y to restore the Service Tag, license, and diagnostics information
A new Dell customer is ordering servers that have very specific firmware dependencies. Any replaced parts of the same type must match the replaced original part identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to accomplish this goal?
- A . Enable the Match Firmware of Replaced Part setting in the system BIOS
- B . Install and configure a repository manager
- C . Configure servers to access the remote firmware repository
- D . Enable the Collect System Inventory On Restart (CSIOR) attribute
While working on a Dell EMC PowerEdge R640 server, a technician accidently removes two fans at the same time.
What should happen to the server?
- A . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server stays operational - B . Remaining fans stay at the recommended RPM
iDRAC slows down the speed of the CPUs to avoid a temperature increase
LCD changes to blue but an alert would have been sent out - C . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server performs a controlled shutdown - D . Remaining fans increase RPM to compensate for the removed fans
LCD changes to blue and displays an error description
Server performs a controlled shutdown
A technician is configuring a PowerEdge R640 that has two PSUs. The rack in which it is being installed has two power distribution units (PDUs). No high power such as GPUs are required. The user wants as must redundancy protection as possible.
What is the best way to configure the PSUs?
- A . Redundancy Mode set to 2+0 with each PSU power cord connected to a different PDU
- B . Redundancy Mode set to1+1 with both PSU power cords connected to the same PDU
- C . Redundancy Mode set to 1+1 with each PSU power cords connected to a different PDU
- D . Redundancy Mode set to 1+0 with the second PSU stored nearby for quick replacement if the first PSU fails