DELL EMC D-PE-OE-23 Practice Exams
Last updated on Oct 22,2026- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Oct 22,2026
A technician working with a Dell EMC PowerEdge 1 take corrective action?
- A . Check the System Event Log
Check PSU LED
Reseat the PSU - B . Check the System Event Log
Check PSU LED
Do a virtual reseat of the iDRAC - C . Check the LCC Log
Check PSU LED
Reseat the CPU - D . Check the LCC Log
Check PSU LED
Reseat the PSU
What is a benefit of an OCP network card?
- A . Allows for link aggregation with the LOM.
- B . Shares a connector with the NDC.
- C . Designed for the Open Connector Framework.
- D . Provides speed and interface flexibility.
A technician receives a repurposed PowerEdge server. After racking and cabling the server, they attempt to log into the iDRAC but cannot do so. The default login account has been disabled.
What method can be used to enable the default login account?
- A . Run the racadm racreset command from the host OS
- B . Boot to F2 and select iDRAC Settings > Reset iDRAC configurations to defaults all
- C . Hold down the i button for 16 seconds
- D . SSH into the iDRAC and run the racadm racreset command
Which iDRAC menu includes the detailed log files required to troubleshoot a hardware issue on a Dell EMC PowerEdge server?
- A . Diagnostics
- B . Maintenance
- C . Troubleshooting
- D . System
A technician needs to improve overall server performance. All servers run a Dell-supported version of RedHat Linux. Turbo boost has been highly beneficial. CPU performance should be maximized, but not at the expense of power usage.
What is the most efficient way to implement these profile options?
- A . In iDRAC, under Hardware Overview > System Performance, select Performance mode
- B . In System BIOS Settings, select Performance per Watt (Operating System)
- C . In System BIOS Settings, select Performance per Watt (Dell Active Power Control)
- D . In iDRAC, under Hardware > CPU, enable Turbo mode and Dell Active Power Control
What is a consideration when populating DIMMs with different types of persistent memory in a Dell EMC PowerEdge 14G server?
- A . NVDIMMs cannot be mixed with RDlMMs
- B . LRDIMMs can be mixed only with RDlMMs
- C . RDlMMs can be mixed only with NVDIMMs
- D . NVDIMMs can be mixed only with LRDIMMs
A technician has a server with the following memory configuration:
– Sixteen 4 GB dual-rank DIMMs
– 8 GB available to the OS
The workload intended for the server required the memory configuration to protect against some errors. Now the technician must deploy for a different workload that requires access to all available memory.
Which setting should the technician change to make all memory available to the system?
- A . Mirrored
- B . Optimizer
- C . Performance
- D . Sparing
A Dell EMC PowerEdge server logs the following CPU Machine Check error: CPU1 IERR.
What action might be required to solve the alert?
- A . Clear logs
- B . Update the Intel driver
- C . Swap the PERC controller
- D . Reseat the IDSDM
What are two requirements for using the iDRACS Quick Sync feature? (Choose two.)
- A . Bluetooth connectivity
- B . Type A/A USB cable
- C . OpenManage Mobile app
- D . NFC enabled mobile device