VMware 2V0-13.24 Practice Exams
Last updated on Nov 16,2026- Exam Code: 2V0-13.24
- Exam Name: VMware Cloud Foundation 5.2 Architect
- Certification Provider: VMware
- Latest update: Nov 16,2026
How can VMware storage performance be optimized when using Broadcom NVMe SSDs?
- A . Implement storage tiering
- B . Use multiple SSDs in RAID 1
- C . Configure NVMe drivers
- D . Enable SSD caching
A, C, D
Explanation:
SSD caching, NVMe driver configuration, and storage tiering are effective for optimizing VMware storage.
Which Broadcom products contribute to improving storage connectivity in VMware Cloud Foundation?
- A . Broadcom NVMe SSDs
- B . Broadcom Ethernet adapters
- C . Broadcom Fibre Channel HBAs
- D . Broadcom RAID controllers
C
Explanation:
Broadcom Fibre Channel HBAs improve storage connectivity in VMware Cloud Foundation.
How can Broadcom storage solutions improve VMware vSAN performance?
- A . High IOPS
- B . Low latency
- C . Seamless integration
- D . Data redundancy
A, B, C, D
Explanation:
High IOPS, low latency, data redundancy, and seamless integration improve vSAN performance with Broadcom storage solutions.
The following storage design decisions were made:
DD01: A storage policy that supports failure of a single fault domain being the server rack.
DD02: Each host will have two vSAN OSA disk groups, each with four 4TB Samsung SSD capacity drives.
DD03: Each host will have two vSAN OSA disk groups, each with a single 300GB Intel NVMe cache drive.
DD04: Disk drives capable of encryption at rest.
DD05: Dual 10Gb or higher storage network adapters.
Which two design decisions would an architect include in the physical design? (Choose two.)
- A . DD01
- B . DD02
- C . DD03
- D . DD04
- E . DD05
B, C
Explanation:
In VMware Cloud Foundation (VCF) 5.2, the physical design specifies tangible hardware and infrastructure choices, while logical design includes policies and configurations. The question focuses on vSAN Original Storage Architecture (OSA) in a VCF environment.
Let’s classify each decision:
Option A: DD01 – A storage policy that supports failure of a single fault domain being the server rack
This is a logical design decision. Storage policies (e.g., vSAN FTT=1 with rack awareness) define data placement and fault tolerance, configured in software, not hardware. It’s not part of the physical design.
Option B: DD02 – Each host will have two vSAN OSA disk groups, each with four 4TB Samsung SSD capacity drives
This is correct. This specifies physical hardware―two disk groups per host with four 4TB SSDs each (capacity tier). In vSAN OSA, capacity drives are physical components, making this a physical design decision for VCF hosts.
Option C: DD03 – Each host will have two vSAN OSA disk groups, each with a single 300GB Intel NVMe cache drive
This is correct. This details the cache tier―two disk groups per host with one 300GB NVMe drive each. Cache drives are physical hardware in vSAN OSA, directly part of the physical design for performance and capacity sizing.
Option D: DD04 – Disk drives capable of encryption at rest
This is a hardware capability but not strictly a physical design decision in isolation. Encryption at rest (e.g., SEDs) is enabled via vSAN configuration and policy, blending physical (drive type) and logical (encryption enablement) aspects. In VCF, it’s typically a requirement or constraint, not a standalone physical choice, making it less definitive here.
Option E: DD05 – Dual 10Gb or higher storage network adapters
This is a physical design decision (network adapters are hardware), but in VCF 5.2, storage traffic (vSAN) typically uses the same NICs as other traffic (e.g., management, vMotion) on a converged network. While valid, DD02 and DD03 are more specific to the storage subsystem’s physical layout, taking precedence in this context.
Conclusion:
The two design decisions for the physical design are DD02 (B) and DD03 (C). They specify the vSAN OSA disk group configuration―capacity and cache drives―directly shaping the physical infrastructure of the VCF hosts.
Reference: VMware Cloud Foundation 5.2 Architecture and Deployment Guide (Section: vSAN OSA Design)
VMware vSAN 7.0U3 Planning and Deployment Guide (integrated in VCF 5.2): Physical Design Considerations
VMware Cloud Foundation 5.2 Planning and Preparation Guide (Section: Storage Hardware)
Which architecture is used by VMware vSphere to manage virtualization workloads?
- A . Clustered
- B . Client-Server
- C . Mainframe
- D . Peer-to-Peer
A, B
Explanation:
vSphere operates using a client-server model with clustered resources.
What are the best practices for optimizing Broadcom network performance in VMware environments?
- A . Disable all offload capabilities
- B . Use VMware network optimization settings
- C . Keep the firmware and drivers updated
- D . Enable network I/O control
B, C, D
Explanation:
Firmware updates, network optimization, and I/O control improve network performance in VMware.
In a large-scale VMware deployment with Broadcom solutions, which components are most important for ensuring both performance and scalability?
- A . vSphere DRS
- B . vSAN
- C . Broadcom RAID Controller
- D . Broadcom 25GbE Ethernet Adapter
A, D
Explanation:
The 25GbE Ethernet Adapter and vSphere DRS are crucial for ensuring performance and scalability in large-scale VMware environments.
Which VMware feature should be prioritized for designing a scalable storage solution with Broadcom hardware?
- A . vSphere DRS
- B . vSphere HA
- C . vCenter Server
- D . vSAN
D
Explanation:
vSAN is the best choice for designing a scalable storage solution in VMware environments with Broadcom hardware.
What is the default file system used for VMFS datastores in vSphere?
- A . ZFS
- B . NTFS
- C . EXT4
- D . VMFS 6
D
Explanation:
VMFS 6 is the default datastore file system for vSphere 6.x and later.
Which vSphere feature allows fault tolerance by running a duplicate VM on another host?
- A . DRS
- B . vSphere Fault Tolerance (FT)
- C . HA
- D . vMotion
B
Explanation:
FT ensures fault tolerance by maintaining a secondary VM on another host.