VMware 2V0-13.24 Practice Exams
Last updated on Nov 16,2026- Exam Code: 2V0-13.24
- Exam Name: VMware Cloud Foundation 5.2 Architect
- Certification Provider: VMware
- Latest update: Nov 16,2026
What are the best practices for troubleshooting VMware storage issues with Broadcom hardware?
- A . Monitor latency and IOPS
- B . Verify disk health status
- C . Reset storage array configuration
- D . Check RAID controller logs
A, B, D
Explanation:
Disk health, RAID logs, and latency monitoring are essential to resolve storage problems in VMware.
Which Broadcom hardware solutions can optimize VMware Cloud Foundation for better performance?
- A . Broadcom RAID storage controllers
- B . Broadcom NVMe storage solutions
- C . Broadcom Ethernet network adapters
- D . Broadcom GPUs
A, B, C
Explanation:
Broadcom’s hardware solutions like Ethernet adapters, NVMe storage, and RAID controllers are integral to optimizing performance in VMware Cloud Foundation.
Which Broadcom products are essential when configuring VMware storage with high throughput?
- A . Broadcom NVMe SSD
- B . vSAN
- C . Fibre Channel HBA
- D . Broadcom 25GbE Ethernet Adapter
A, B, D
Explanation:
Broadcom 25GbE Ethernet Adapters, NVMe SSDs, and vSAN are critical for high-throughput VMware storage configuration.
An organization is planning to expand their existing VMware Cloud Foundation (VCF) environment to meet an increased demand for new user-facing applications. The physical host hardware proposed for the expansion is a different model compared to the existing hosts, although it has been confirmed that both sets of hardware are compatible. The expansion needs to provide capacity for management tooling workloads dedicated to the applications, and it has been decided to deploy a new cluster within the management domain to host the workloads.
What should the architect include within the logical design for this design decision?
- A . The design justification stating that the separate cluster provides flexibility for manageability and connectivity of the workloads
- B . The design assumption stating that the separate cluster will provide complete isolation for lifecycle management
- C . The design implication stating that the management tooling and the VCF management workloads have different purposes
- D . The design qualities affected by the decision listed as Availability and Performance
A
Explanation:
In VCF, the logical design documents how design decisions align with requirements, often through justifications, assumptions, or implications. Here, adding a new cluster within the management domain for dedicated management tooling workloads requires a rationale in the logical design.
Option A, a justification that the separate cluster enhances "flexibility for manageability and connectivity," aligns with VCF’s principles of workload segregation and operational efficiency. It explains why the decision was made―improving management tooling’s flexibility―without assuming unstated outcomes (like B’s "complete isolation," which isn’t supported by the scenario) or merely stating effects (C and D). The management domain in VCF 5.2 can host additional clusters for such purposes, and this justification ties directly to the requirement for dedicated capacity.
Reference: VMware Cloud Foundation 5.2 Planning and Preparation Guide, Chapter 4: Logical Design Considerations, Section on Design Justifications.
What key technologies support data protection and security standards in VMware environments using Broadcom hardware?
- A . VMware vSphere Encryption
- B . VMware Site Recovery Manager
- C . VMware NSX Distributed Firewall
- D . Broadcom Storage Security
A, B, C, D
Explanation:
VMware vSphere Encryption, Site Recovery Manager, Broadcom Storage Security, and NSX Distributed Firewall enhance data protection and security.
An architect has been tasked with reviewing a VMware Cloud Foundation design document.
Observe the following requirements:
REQ01: The solution must support the private cloud cybersecurity industry and local standards and controls.
REQ02: The solution must ensure that the cloud services are transitioned to operation teams.
REQ03: The solution must provide a self-service portal.
REQ04: The solution must provide the ability to consume storage based on policies.
REQ05: The solution should provide the ability to extend networks between different availability zones.
Observe the following design decisions:
DD01: There will be a clustered deployment of Aria Automation.
DD02: There will be an integration between Aria Automation and multiple geo-located vCenter Servers.
Based on the information provided, which two requirements satisfy the stated design decisions? (Choose two.)
- A . REQ01
- B . REQ02
- C . REQ03
- D . REQ04
- E . REQ05
C, E
Explanation:
In VMware Cloud Foundation (VCF) 5.2, VMware Aria Automation (formerly vRealize Automation) enhances the platform by providing self-service, automation, and multi-site management capabilities. The architect must determine which requirements (REQ01-REQ05) are directly satisfied by the design decisions (DD01 and DD02).
Let’s evaluate each requirement against the decisions:
Design Decisions:
DD01: Clustered deployment of Aria Automation
A clustered deployment ensures high availability and scalability of Aria Automation, supporting multiple users and workloads with resilience.
DD02: Integration between Aria Automation and multiple geo-located vCenter Servers
This enables centralized management of distributed vSphere environments (e.g., across availability zones or regions), facilitating network and resource orchestration.
Evaluation of Requirements:
Option A: REQ01 – The solution must support the private cloud cybersecurity industry and local standards and controls
This requirement focuses on cybersecurity and compliance (e.g., encryption, access controls, auditing). While Aria Automation supports role-based access control (RBAC) and integrates with secure VCF components, neither DD01 nor DD02 directly addresses cybersecurity standards or local controls. These are typically met by VCF’s baseline security features (e.g., NSX, vSphere hardening), not specifically by Aria Automation’s clustering or vCenter integration. Thus, REQ01 is not directly satisfied by the stated decisions.
Option B: REQ02 – The solution must ensure that the cloud services are transitioned to operation teams
This requirement implies operational handoff, training, or automation to enable operations teams to manage services. Aria Automation’s clustering (DD01) improves reliability, and vCenter integration (DD02) centralizes management, but neither explicitly ensures a transition process (e.g., documentation, runbooks). This is more about operational processes than the technical decisions provided, so REQ02 is not directly satisfied.
Option C: REQ03 – The solution must provide a self-service portal
This is correct. Aria Automation’s primary function in VCF 5.2 is to provide a self-service portal for users to provision and manage resources (e.g., VMs, applications). A clustered deployment (DD01) ensures the portal’s availability and scalability, supporting multiple users concurrently. Integration with vCenter Servers (DD02) enhances its capability to deploy resources across sites, but DD01 alone directly satisfies REQ03 by enabling a robust self-service experience. Thus, REQ03 is satisfied.
Option D: REQ04 – The solution must provide the ability to consume storage based on policies
This requirement involves policy-driven storage management (e.g., vSAN storage policies). Aria Automation supports storage policies via integration with vSphere/vSAN, allowing users to define storage profiles (e.g., performance, capacity). However, this capability is inherent to vSphere/vSAN integration, not uniquely tied to clustering (DD01) or geo-located vCenter integration (DD02). While Aria Automation facilitates this, the design decisions don’t specifically address storage policy consumption as a primary outcome, making REQ04 less directly satisfied compared to others.
Option E: REQ05 – The solution should provide the ability to extend networks between different availability zones
This is correct. Integrating Aria Automation with multiple geo-located vCenter Servers (DD02) enables management of distributed environments, including network extension across availability zones. In VCF 5.2, this leverages NSX-T for Layer 2 stretching (e.g., via HCX or NSX Federation), orchestrated through Aria Automation. DD02 directly supports this by connecting disparate vCenters, allowing network policies and extensions to be applied across zones. Clustering (DD01) supports scalability but isn’t the key factor―DD02 is the primary enabler. Thus, REQ05 is satisfied.
Conclusion:
The two requirements satisfied by the design decisions are:
REQ03 (C): A clustered Aria Automation deployment (DD01) directly provides a reliable self-service
portal.
REQ05 (E): Integration with multiple geo-located vCenter Servers (DD02) enables network extension across availability zones.
While REQ04 is partially supported, REQ03 and REQ05 are the most directly tied to the stated decisions in the VCF 5.2 context.
Reference: VMware Cloud Foundation 5.2 Architecture and Deployment Guide (Section: Aria Automation Integration)
VMware Aria Automation 8.10 Documentation (integrated in VCF 5.2): Self-Service Portal and Multi-Site Management
VMware NSX-T 3.2 Reference Design (integrated in VCF 5.2): Network Extension Capabilities
A customer has a database cluster running in a VCF cluster with the following characteristics:
40/60 Read/Write ratio.
High IOPS requirement.
No contention on an all-flash OSA vSAN cluster in a VI Workload Domain.
Which two vSAN configuration options should be configured for best performance? (Choose two.)
- A . Flash Read Cache Reservation
- B . RAID 1
- C . Deduplication and Compression disabled
- D . Deduplication and Compression enabled
- E . RAID 5
B, C
Explanation:
The database cluster in a VCF 5.2 VI Workload Domain uses an all-flash vSAN Original Storage Architecture (OSA) cluster with a 40/60 read/write ratio, high IOPS needs, and no contention (implying sufficient resources). vSAN configuration impacts performance, especially for databases. Let’s evaluate:
Option A: Flash Read Cache Reservation
In all-flash vSAN OSA, the cache tier (flash) serves writes, not reads, which are handled by the capacity tier (also flash). The vSAN Planning and Deployment Guide notes that Flash Read Cache Reservation is deprecated for all-flash configurations, as reads don’t benefit from caching, making this irrelevant for performance here.
Option B: RAID 1
RAID 1 (mirroring) replicates data across hosts, offering high performance and availability (FTT=1). For a 40/60 read/write workload with high IOPS, RAID 1 minimizes latency and maximizes throughput compared to erasure coding (e.g., RAID 5), as it avoids parity calculations. The VCF 5.2 Architectural Guide recommends RAID 1 for performance-critical workloads like databases, especially with no contention.
Option C: Deduplication and Compression disabled
Disabling deduplication and compression avoids CPU overhead and latency from data processing, critical for high-IOPS workloads. The vSAN Administration Guide advises disabling these for performance-sensitive applications (e.g., databases), as the 60% write ratio benefits from direct I/O over space efficiency, given no contention.
Option D: Deduplication and Compression enabled
Enabling deduplication and compression reduces storage use but increases latency and CPU load, degrading performance for high-IOPS workloads. The vSAN Planning and Deployment Guide notes this trade-off, making it unsuitable here.
Option E: RAID 5
RAID 5 (erasure coding) uses parity, reducing write performance due to calculations, which conflicts with the 60% write ratio and high IOPS needs. The VCF 5.2 Architectural Guide recommends RAID 5 for capacity optimization, not performance, favoring RAID 1 instead.
Conclusion:
B: RAID 1 ensures high performance for IOPS and write-heavy workloads.
C: Disabling deduplication and compression optimizes I/O performance. These align with vSAN best practices for all-flash database clusters in VCF 5.2.
Reference: VMware Cloud Foundation 5.2 Architectural Guide (docs.vmware.com): vSAN Configuration for Performance.
vSAN Planning and Deployment Guide (docs.vmware.com): RAID Levels and All-Flash Settings.
vSAN Administration Guide (docs.vmware.com): Deduplication and Compression Impact.
What Broadcom components are required to maintain VMware storage performance in a large-scale environment?
- A . Broadcom NVMe SSD
- B . vSAN
- C . 25GbE Ethernet Adapter
- D . Broadcom RAID Controller
A, B, D
Explanation:
Broadcom RAID Controllers, NVMe SSDs, and vSAN are essential to maintaining VMware storage performance at scale.
When designing a cost-effective VMware environment with Broadcom solutions, which components should be prioritized?
- A . Broadcom 25GbE Ethernet Adapter
- B . Broadcom RAID Controller
- C . vSAN
- D . vSphere HA
A, C, D
Explanation:
Broadcom 25GbE Ethernet Adapters, vSphere HA, and vSAN are cost-effective solutions for VMware environments.
An architect is designing a VMware Cloud Foundation (VCF)-based private cloud solution for a customer.
The customer has stated the following requirement:
All components within the solution must be resilient to N+1.
During discovery, the following information has also been provided:
Over the next 3 years, due to various applications being retired, no overall growth in resource consumption is expected.
Following a review of a demand-based capacity report from Aria Operations, the architect has calculated that all of the existing workloads should fit into a 4-node cluster. Once all workloads are migrated, the resources of the cluster will be 90% utilized.
Given the information provided, a combination of which three design decisions satisfy the requirement? (Choose three.)
- A . The solution will set the DRS Automation level setting for the workload cluster to Partially Automated.
- B . The solution will deploy a workload cluster consisting of five VMware vSphere hosts.
- C . The solution will set the Host failures cluster tolerates for the workload cluster to 1.
- D . The solution will deploy a workload cluster consisting of four VMware vSphere hosts.
- E . The solution will configure vSphere High Availability (HA) for the workload cluster.
- F . The solution will configure vSphere Dynamic Resource Scheduling (DRS) for the workload cluster.
B, C, E
Explanation:
The requirement for N+1 resiliency means the solution must tolerate the failure of one component (in this case, one ESXi host) without disrupting workloads. In VMware Cloud Foundation (VCF), this is typically achieved through vSphere High Availability (HA) settings and sufficient host capacity. The scenario provides key constraints: a 4-node cluster can handle all workloads at 90% utilization, and no growth is expected.
Let’s evaluate each option:
Option A: Set the DRS Automation level to Partially Automated
DRS (Dynamic Resource Scheduling) balances workloads across hosts, but the automation level (Partially Automated vs. Fully Automated) doesn’t directly impact N+1 resiliency. Partially Automated requires manual approval for migrations, which doesn’t enhance or detract from HA-based resiliency. While DRS is useful, this specific setting isn’t critical to the N+1 requirement, per the VMware Cloud Foundation 5.2 Architectural Guide.
Option B: Deploy a workload cluster consisting of five VMware vSphere hosts
A 5-node cluster provides N+1 resiliency when paired with HA configured to tolerate one host failure. If one host fails, the remaining four can handle the workload, assuming capacity planning accounts for this. The Aria Operations report indicates a 4-node cluster is sufficient at 90% utilization, but adding a fifth host ensures capacity remains after a failure (reducing utilization to ~72% across four hosts: 90% / 1.25). This aligns with VCF’s standard architecture recommendations for resiliency (VMware Cloud Foundation 5.2 Architectural Guide).
Option C: Set the Host failures cluster tolerates for the workload cluster to 1
This HA setting ensures the cluster reserves capacity (e.g., CPU and memory) to failover VMs from one failed host. In VCF, setting “Host failures cluster tolerates” to 1 is a direct implementation of N+1 resiliency, making it a required design decision (vSphere Availability Guide and VCF 5.2 Administration Guide).
Option D: Deploy a workload cluster consisting of four VMware vSphere hosts
A 4-node cluster meets capacity needs at 90% utilization but lacks N+1 resiliency without additional capacity. If one host fails, the remaining three would be overcommitted (120% utilization: 90% / 0.75), risking performance or availability. Thus, this doesn’t satisfy the requirement alone.
Option E: Configure vSphere High Availability (HA) for the workload cluster
HA is foundational to N+1 resiliency in vSphere and VCF, enabling VM restarts on surviving hosts after a failure. Without HA, N+1 cannot be achieved, making this a mandatory choice (VMware Cloud Foundation 5.2 Administration Guide).
Option F: Configure vSphere Dynamic Resource Scheduling (DRS) for the workload cluster
DRS enhances performance by balancing workloads but isn’t strictly required for N+1 resiliency, which focuses on availability, not optimization. It’s a best practice in VCF but not one of the three critical decisions for this requirement.
Conclusion:
B: A 5-node cluster provides the extra host for N+1.
C: HA set to tolerate 1 host failure implements N+1 policy.
E: HA configuration enables failover, a core N+1 component.
Options B, C, and E together ensure the cluster can lose one host without service disruption, meeting the customer’s requirement.
Reference: VMware Cloud Foundation 5.2 Architectural Guide (docs.vmware.com): Section on Workload Domain Design and HA/DRS Configuration.
vSphere Availability Guide (docs.vmware.com): Chapter on Configuring High Availability.
VMware Cloud Foundation 5.2 Administration Guide (docs.vmware.com): HA and Cluster Sizing Guidelines.