VMware 2V0-13.24 Practice Exams
Last updated on Nov 16,2026- Exam Code: 2V0-13.24
- Exam Name: VMware Cloud Foundation 5.2 Architect
- Certification Provider: VMware
- Latest update: Nov 16,2026
Which VMware tools contribute to automating resource management in VMware Cloud Foundation?
- A . VMware vRealize Orchestrator
- B . VMware vSphere
- C . VMware vRealize Operations
- D . VMware vRealize Automation
A, C, D
Explanation:
VMware Cloud Foundation benefits from automation through tools like vRealize Automation, Orchestrator, and Operations.
Which component is responsible for managing multiple ESXi hosts in a vSphere environment?
- A . NSX-T Manager
- B . vSAN
- C . vCenter Server
- D . ESXi
C
Explanation:
vCenter Server is the core management component in a vSphere environment.
Which VMware solutions can leverage Broadcom’s SmartNIC technology for enhanced performance?
- A . VMware vSphere
- B . VMware vCloud Director
- C . VMware NSX-T
- D . VMware vSAN
A, B, C, D
Explanation:
VMware vSphere, vSAN, NSX-T, and vCloud Director can all benefit from Broadcom’s SmartNIC technology for enhanced performance.
Which Broadcom products are essential for enhancing network performance in VMware Cloud Foundation environments?
- A . Broadcom RAID controllers
- B . Broadcom NVMe SSDs
- C . Broadcom Fibre Channel HBAs
- D . Broadcom Ethernet adapters
D
Explanation:
Broadcom Ethernet adapters are essential for network performance in VMware Cloud Foundation.
A customer is deploying VCF at a new datacenter location. They will migrate their workloads from the existing datacenter to the new VCF platform over six months. Both datacenters will run simultaneously for six months during the migration.
Which of the following should be a documented risk?
- A . Six months may not be enough time to complete the migration.
- B . There will be connectivity between the two locations.
- C . Bandwidth between the two locations is sufficient to accommodate the workload migration.
- D . Workloads will be powered off during migration.
A
Explanation:
In VCF design, risks are potential issues that could jeopardize project success, documented to prompt mitigation planning.
Option A, "Six months may not be enough time to complete the migration," is a valid risk because workload migration complexity (e.g., application dependencies, data volume, testing) could exceed the timeline, a common challenge in VCF deployments.
Option B (connectivity) is a fact, not a risk, unless qualified as unreliable.
Option C (sufficient bandwidth) is an assumption or requirement, not a risk unless proven inadequate.
Option D (powering off workloads) is a design choice, not an inherent risk without evidence. VCF migration planning emphasizes timeline risks, making A the best choice.
Reference: VMware Cloud Foundation 5.2 Planning and Preparation Guide, Chapter 5: Risk Assessment; VMware Migration Best Practices for VCF.
The following requirements were identified in an architecture workshop for a VMware Cloud Foundation (VCF) design project using vSAN as the primary storage solution:
REQ001: The application must maintain a minimum of 1,000 transactions per second (TPS) during business hours, excluding disaster recovery (DR) scenarios.
REQ002: Automatic DRS and HA must be utilized.
REQ003: Planned maintenance must be performed outside of business hours.
While monitoring the TPS of the application, which of the following is NOT a valid test case to validate these requirements?
- A . Trigger a vSphere High Availability (HA) failover activity.
- B . Trigger a vSAN disk group cache drive failure.
- C . Trigger fully automatic DRS vMotion activity.
- D . Trigger a vCenter upgrade workflow.
D
Explanation:
The test case must validate all three requirements: maintaining 1,000 TPS during business hours (REQ001), using automatic DRS and HA (REQ002), and ensuring maintenance occurs outside business hours (REQ003, implying minimal disruption during business hours).
Let’s assess each:
Option A: Trigger a vSphere High Availability (HA) failover activity
HA failover (e.g., host failure) tests automatic VM restarts (REQ002) and ensures TPS (REQ001) remains at 1,000 during business hours under failure conditions (excluding DR, as this is intra-site). The VCF 5.2 Administration Guide recommends HA testing to validate availability, making this valid.
Option B: Trigger a vSAN disk group cache drive failure
A cache drive failure in vSAN tests data resilience and HA’s ability to restart VMs if needed (REQ002), while monitoring TPS (REQ001) during business hours. The vSAN Administration Guide supports this as a standard test for vSAN performance and recovery, aligning with the requirements.
Option C: Trigger fully automatic DRS vMotion activity
Fully automatic DRS triggers vMotion to balance loads (REQ002), testing TPS (REQ001) during business hours without disruption. While not maintenance, it validates DRS automation’s impact on performance, per the vSphere Resource Management Guide, making it a valid test.
Option D: Trigger a vCenter upgrade workflow
A vCenter upgrade is a planned maintenance activity (REQ003) that should occur outside business hours. Performing it during business hours to monitor TPS contradicts REQ003 and isn’t a typical test for DRS/HA (REQ002) or application performance (REQ001), as it affects management, not workloads directly. The VCF 5.2 Administration Guide treats upgrades as separate from runtime validation.
Conclusion:
Option D is not a valid test case, as it violates REQ003 and doesn’t directly validate REQ001 or REQ002 in a runtime context.
Reference: VMware Cloud Foundation 5.2 Administration Guide (docs.vmware.com): HA and vSAN Testing.
vSphere Resource Management Guide (docs.vmware.com): DRS Automation Testing.
vSAN Administration Guide (docs.vmware.com): Disk Failure Scenarios.
Which actions can help optimize VMware storage performance when using Broadcom RAID controllers?
- A . Implement RAID 10 for high performance and redundancy
- B . Use Broadcom SSDs for cache
- C . Use RAID 6 for more fault tolerance
- D . Increase cache memory
A, B, D
Explanation:
Using RAID 10, SSDs for cache, and increasing cache memory will enhance storage performance.
In a VMware environment with Broadcom solutions, which components are essential for minimizing network bottlenecks?
- A . vSAN
- B . Broadcom 25GbE Ethernet Adapter
- C . Fibre Channel HBA
- D . vSphere Distributed Switch (VDS)
B, D
Explanation:
Broadcom 25GbE Ethernet Adapters and vSphere Distributed Switch (VDS) help reduce network bottlenecks in VMware environments.
Which statement defines the purpose of Technical Requirements?
- A . Technical requirements define which goals and objectives can be achieved.
- B . Technical requirements define what goals and objectives need to be achieved.
- C . Technical requirements define which audience needs to be involved.
- D . Technical requirements define how the goals and objectives can be achieved.
D
Explanation:
In VMware’s design methodology, as outlined in the VMware Cloud Foundation 5.2 Architectural Guide, requirements are categorized into Business Requirements (high-level organizational goals) and Technical Requirements (specific system capabilities or constraints to achieve those goals).
Technical Requirements bridge the gap between what the business wants and how the solution delivers it. Let’s evaluate each option:
Option A: Technical requirements define which goals and objectives can be achieved
This suggests Technical Requirements determine feasibility, which aligns more with a scoping or assessment phase, not their purpose. VMware documentation positions Technical Requirements as implementation-focused, not evaluative.
Option B: Technical requirements define what goals and objectives need to be achieved
This describes Business Requirements, which outline “what” the organization aims to accomplish (e.g., reduce costs, improve uptime). Technical Requirements specify “how” these are realized, making this incorrect.
Option C: Technical requirements define which audience needs to be involved
Audience involvement relates to stakeholder identification, not Technical Requirements. The VCF 5.2 Design Guide ties Technical Requirements to system functionality, not personnel.
Option D: Technical requirements define how the goals and objectives can be achieved
This is correct. Technical Requirements detail the system’s capabilities, constraints, and configurations (e.g., “support 10,000 users,” “use AES-256 encryption”) to meet business goals. The VCF 5.2 Architectural Guide defines them as the “how”―specific, measurable criteria enabling the
solution’s implementation.
Conclusion:
Option D accurately reflects the purpose of Technical Requirements in VCF 5.2, focusing on the means to achieve business objectives.
Reference: VMware Cloud Foundation 5.2 Architectural Guide (docs.vmware.com): Section on Requirements Classification.
VMware Cloud Foundation 5.2 Design Guide (docs.vmware.com): Business vs. Technical Requirements.
Which Broadcom components are needed to ensure optimal storage reliability in VMware environments?
- A . Broadcom RAID Controller
- B . vSAN
- C . VMware Fault Tolerance
- D . Broadcom NVMe SSD
A
Explanation:
Broadcom RAID Controllers are necessary for ensuring optimal storage reliability in VMware environments.