VMware 2V0-13.24 Practice Exams
Last updated on Nov 16,2026- Exam Code: 2V0-13.24
- Exam Name: VMware Cloud Foundation 5.2 Architect
- Certification Provider: VMware
- Latest update: Nov 16,2026
What are the benefits of using Broadcom Fibre Channel HBAs in VMware environments?
- A . Improved Network Latency
- B . Scalability
- C . High-speed SAN Connectivity
- D . Data Redundancy
C, D
Explanation:
Broadcom Fibre Channel HBAs provide high-speed SAN connectivity and data redundancy in VMware environments.
What is the maximum RAM supported per virtual machine in vSphere 8.x?
- A . 8 TB
- B . 24 TB
- C . 6 TB
- D . 12 TB
D
Explanation:
vSphere 8.x supports up to 12 TB of RAM per VM.
What is the key consideration when selecting Broadcom hardware for a VMware environment requiring low-latency networking?
- A . Broadcom 25GbE Ethernet Adapter
- B . Broadcom 10GbE Ethernet Adapter
- C . Broadcom NVMe SSD
- D . Broadcom RAID Controller
A
Explanation:
The Broadcom 25GbE Ethernet Adapter is critical for achieving low-latency networking in a VMware environment.
Which VMware Cloud Foundation features improve scalability in hybrid cloud environments?
- A . VMware vSAN
- B . VMware NSX
- C . VMware vSphere
- D . VMware vRealize Automation
A, B, C, D
Explanation:
VMware vSphere, vSAN, NSX, and vRealize Automation enhance scalability in hybrid cloud environments.
Which storage protocol is commonly used by VMware vSphere to access SAN devices?
- A . NFS
- B . Fibre Channel
- C . SMB
- D . iSCSI
D
Explanation:
iSCSI is commonly used for accessing SAN devices in vSphere.
An architect is working on higher-scale NSX Grouping and security design requirements for Management and VI Workload Domains in VMware Cloud Foundation.
Which NSX Manager appliance size will be considered for use?
- A . Extra Large
- B . Large
- C . Medium
- D . Small
B
Explanation:
In VMware Cloud Foundation (VCF) 5.2, NSX Manager appliances manage networking and security (e.g., grouping, policies, firewalls) for Management and VI Workload Domains. The appliance size― Small, Medium, Large, Extra Large―determines its capacity to handle scale, such as the number of hosts, VMs, and security objects. The phrase “higher scale” implies a larger-than-minimum deployment.
Let’s evaluate:
NSX Manager Appliance Sizes (VCF 5.2 with NSX-T 3.2):
Small: 4 vCPUs, 16 GB RAM, 300 GB disk. Supports up to 16 hosts, basic deployments (e.g., lab environments).
Medium: 6 vCPUs, 24 GB RAM, 300 GB disk. Supports up to 64 hosts, suitable for small to medium production environments.
Large: 12 vCPUs, 48 GB RAM, 300 GB disk. Supports up to 512 hosts, 10,000 VMs, and complex security policies―standard for production VCF.
Extra Large: 24 vCPUs, 64 GB RAM, 300 GB disk. Supports over 512 hosts, massive scale (e.g., service providers, multi-VCF instances).
VCF Context:
Management Domain: Minimum 4 hosts, often 6-7 for HA, with NSX for overlay networking.
VI Workload Domains: Variable host counts, but “higher scale” suggests multiple domains or significant workload growth.
Security Design: Grouping and policies (e.g., distributed firewall rules, tags) increase NSX Manager load, especially at scale.
Evaluation:
Small: Insufficient for production VCF, limited to 16 hosts. Unsuitable for a Management Domain (4-7 hosts) plus VI Workload Domains.
Medium: Adequate for small VCF deployments (up to 64 hosts), but “higher scale” implies more hosts or complex security, exceeding its capacity.
Large: The default and recommended size for VCF 5.2 production environments. It supports up to 512 hosts, thousands of VMs, and extensive security policies, fitting a Management Domain and multiple VI Workload Domains with “higher scale” needs.
Extra Large: Overkill unless managing hundreds of hosts or multiple VCF instances, which isn’t indicated here.
Conclusion:
The Large NSX Manager appliance size (Option B) is appropriate for a higher-scale NSX design in VCF 5.2. It balances capacity and performance for Management and VI Workload Domains with advanced security requirements, aligning with VMware’s standard recommendation.
Reference: VMware Cloud Foundation 5.2 Architecture and Deployment Guide (Section: NSX Manager Sizing)
NSX-T 3.2 Installation Guide (integrated in VCF 5.2): Appliance Size Specifications
VMware Cloud Foundation 5.2 Planning and Preparation Guide (Section: Security Design)
Which Broadcom components should be considered when designing a high-availability VMware environment?
- A . 25GbE Ethernet Adapter
- B . Broadcom NVMe SSD
- C . vSphere HA
- D . Broadcom RAID Controller
A, C, D
Explanation:
vSphere HA, Broadcom RAID Controllers, and 25GbE Ethernet Adapters are essential for high availability in VMware environments.
A customer has a requirement to improve bandwidth and reliability for traffic that is routed through the NSX Edges in VMware Cloud Foundation.
What should the architect recommend satisfying this requirement?
- A . Configure a Load balanced Group for NSX Edges
- B . Configure a TEP Group for NSX Edges
- C . Configure a TEP Independent Group for NSX Edges
- D . Configure a LAG Group for NSX Edges
D
Explanation:
In VCF, NSX Edges handle north-south traffic, and improving bandwidth and reliability involves optimizing their network connectivity.
Option D, "Configure a LAG Group for NSX Edges," uses Link Aggregation Groups (LAG) to bundle multiple physical links, increasing bandwidth and providing redundancy via failover if a link fails. This aligns with NSX-T 3.2 capabilities in VCF 5.2 for edge nodes, directly addressing the requirement.
Option A (load balancing) could distribute traffic but doesn’t inherently improve physical link reliability, while B and C (TEP groups) relate to host-level Tunnel
Endpoints, not edge traffic. LAG is a standard NSX recommendation for such scenarios.
Reference: NSX-T 3.2 Administration Guide (included in VCF 5.2), Section on Edge Networking and Link Aggregation; VMware Cloud Foundation 5.2 Networking Guide.
Which vSphere feature allows virtual machines to access shared storage?
- A . Snapshots
- B . Distributed Switch
- C . Datastores
- D . vSAN
C
Explanation:
Datastores enable shared storage access for VMs.
An architect has been tasked with reviewing a VMware Cloud Foundation design document.
Observe the following requirements:
• REQ01: The solution must provide the ability to request new tenant creation with multi-site and different size options.
• REQ02: The solution must provide the capability to monitor the software-defined data center for capacity and performance.
• REQ03: The solution must provide the ability to generate reports with customized metrics to meet business requests.
• REQ04: The solution should report all capacity planning components (such as current capacity usage monthly and annual usage growth).
• REQ05: The solution must provide the ability to provision new virtual machines from predefined templates.
• REQ06: The solution must provide a self-service catalog for end-users to consume services. Observe the following design decisions:
• DD01: There will be a centralized deployment of Aria Operations Management.
• DD02: There will be customized super-metrics based on existing metrics.
Based on the stated requirements and design decisions, which three requirements does this design decision satisfy? (Choose three.)
- A . REQ05
- B . REQ01
- C . REQ06
- D . REQ04
- E . REQ03
- F . REQ02
D, E, F
Explanation:
Aria Operations in VCF 5.2 provides monitoring and analytics. DD01 (centralized Aria Operations) enables REQ02 (F) by monitoring SDDC capacity and performance across domains. DD02 (customized super-metrics) supports REQ03 (E) by allowing tailored reports and REQ04 (D) by enabling capacity planning with usage trends. REQ01 (B) and REQ06 (C) require Aria Automation for tenant creation and self-service, not Operations. REQ05 (A) involves provisioning, also an Automation function. Thus, D, E, F are satisfied by these decisions.
Reference: VMware Aria Operations 8.10 Administration Guide, Capacity and Custom Metrics; VMware Cloud Foundation 5.2 Architect Study Guide, Monitoring Solutions.