Netapp NS0-014 Practice Exams
Last updated on Oct 22,2026- Exam Code: NS0-014
- Exam Name: NetApp Implementation Engineer MetroCluster Specialist (NCIE-MetroCluster)
- Certification Provider: Netapp
- Latest update: Oct 22,2026
What are two key indicators of a successful switchover test in a MetroCluster environment? (Select two)
- A . All data services remain available during the test
- B . The secondary site remains in read-only mode
- C . Replication traffic switches to the secondary site
- D . Replication traffic switches to the secondary site
Which two configuration steps are essential when installing MetroCluster Tiebreaker software? (Select two)
- A . Configure cross-site LIFs
- B . Install ONTAP Mediator
- C . Set up IP connectivity between clusters
- D . Enable SyncMirror
What are two core components of a MetroCluster IP architecture? (Select two)
- A . SyncMirror
- B . ATTO FibreBridge
- C . Fibre Channel switches
- D . Inter-Switch Links (ISLs)
What is the primary role of the ATTO FibreBridge in a MetroCluster configuration?
- A . Convert IP to Fibre Channel traffic
- B . Provide redundancy for network paths
- C . Connect disk shelves to controllers
- D . Optimize network performance
During the planning phase, which component is used to manage and monitor the MetroCluster environment?
- A . Active IQ Unified Manager
- B . System CLI
- C . Cloud Manager
- D . MetroCluster Manager
In an IP-based MetroCluster configuration, which component is responsible for managing communication between cluster nodes at different sites?
- A . SnapVault
- B . Inter-Switch Links (ISLs)
- C . Cluster Interconnect
- D . ATTO Bridge
Which tool is used to perform a disaster recovery simulation in an IP MetroCluster environment?
- A . ONTAP Mediator
- B . MetroCluster Tiebreaker
- C . MetroCluster Switchover Simulator
- D . OnCommand System Manager
What is a critical requirement for transitioning a MetroCluster environment from 7-Mode to Clustered ONTAP?
- A . Reconfiguring IP switches
- B . Using the 7-Mode Transition Tool
- C . Replacing all storage hardware
- D . Manually updating all ONTAP licenses
Which task must be completed first when upgrading MetroCluster hardware components?
- A . Update the ONTAP software
- B . Validate system compatibility using IMT
- C . Install new ATTO FibreBridges
- D . Install the Mediator software
When transitioning from FC to IP MetroCluster, which two components must be replaced? (Select two)
- A . Fibre Channel switches
- B . ATTO FibreBridges
- C . Ethernet switches
- D . Mediator software