DELL EMC D-PEMX-DY-23 Practice Exams
Last updated on Oct 22,2026- Exam Code: D-PEMX-DY-23
- Exam Name: Dell PowerEdge MX Modular Deploy 2023 Exam
- Certification Provider: DELL EMC
- Latest update: Oct 22,2026
A PowerEdge MX7000 chassis was ordered with a factory-generated password. The customer needs to reset the PowerEdge MX7000 chassis configuration using the RACADM racresetcfg command.
What login credentials will the customer need to use to log on after running the command?
- A . root / calvin
- B . admin / password found on luggage tag
- C . root / password found on luggage tag
- D . admin / calvin
What type of power cord connects to the PSU side of a PowerEdge MX7000?
- A . C13
- B . C15
- C . C15
- D . C21
Which MX7000 chassis components does the Vertical Power Distribution Board power?
- A . IOMs
Compute sleds
Rear fans - B . Compute sleds
Right and Left Control Panels
Rear fans - C . IOMs
Rear fans
Front fans
An administrator has been tasked with specifying hardware for a deployment having the following requirements:
4 node cluster within a single MX7000 chassis
Each node needs a minimum of 6x 2.5" drives
3 TB of memory and 64 physical CPU cores per node
What is the maximum hardware configuration that meets the requirements?
- A . MX740c with no storage sleds
- B . MX740c with MX5016s storage sleds
- C . MX840c with no storage sleds
- D . MX 840c with MX5016s storage sleds
In an MX7000, which components are cooled by the rear fans?
- A . Fabric A, B, and C IOMs only
- B . All compute and storage sleds
- C . Management Modules only
- D . Fabric A, B, and C IOMs and the Management Modules
To which component can a firmware update be applied without affecting any applications running on the server?
- A . NIC
- B . RAID Controller
- C . BIOS
- D . iDRAC
How can a hard reset be performed on iDRAC?
- A . On the iDRAC web interface, select the Reset option
- B . Using the OME-M Interface and selecting Virtual Reseat
- C . On the server, press and hold the ID LED button for 15 seconds
- D . Using the RACADM command –SystemReset -t 0 Cf
Refer to the exhibit.

A customer recently replaced all the dual-port network cards in mezzanine A with quad-port network cards across all 16 PowerEdge MX740c sleds in the two-chassis configuration. The customer can only access half of the network ports, even though the quad-port cards are visible in the iDRAC.
What actions are required to resolve the problem?
- A . Do a virtual reseat of all the MX740c sleds.
Update the firmware on all the quad port network cards.
Adjust the switch configuration to use the new ports. - B . Install a new 200G cable from port 3 on the MX7116n in chassis 2 slot A1 into port 19 on the MX9116n in chassis 1 slot A1.
Do the same for the switches in slots A2.
Adjust the switch configuration to use the new ports. - C . Reboot the switches.
Adjust the switch configuration to use the new ports. - D . Reseat all the switches.
Adjust the switch configuration to use the new ports.
What types of network shares are supported for hosting the firmware catalog for a PowerEdge MX7000 chassis?
- A . HTTP, HTTPS, FTP, and SFTP
- B . NFS, CIFS, HTTP, and HTTPS
- C . SCP, FTP, NFS, and HTTPS
- D . SMB, SFTP, NFS, and FTP
An administrator needs to start collecting detailed data points on the PowerEdge MX7000 power usage.
What is the minimum requirement?
- A . OME-M Basic
- B . OpenManage Enterprise
- C . OpenManage Essentials
- D . OME-M Advanced