DELL EMC D-PE-FN-01 Practice Exams
Last updated on Oct 22,2026- Exam Code: D-PE-FN-01
- Exam Name: Dell PowerEdge Foundations v2 Exam
- Certification Provider: DELL EMC
- Latest update: Oct 22,2026
What is the purpose of the DNS role?
- A . Send out emails from a server to a client
- B . Translate domain names into IP address
- C . transfer computer files between a client and a server
- D . Distribute and update dynamic IP address
What is the object of server configuration management in an environment?
- A . Minimize cost of server and to extend the lifetime of servers being used
- B . Reduce cost servers regardless of workload types, or performance requirements
- C . Maximum performance per watt at all utilization levels and workload types while performance requirements
- D . Maximize server performance, regardless of workload, utilization or performance requirements
Which type of cables are shown in the graphic?

- A . Coaxial
- B . Copper
- C . Fibre
- D . UTP
Which document provides the computer hardware that has been tested to pass Microsoft standards of compatibility, reliability, security, and applications for all Dell EMC PowerEdge Servers?
- A . HML
- B . BCL
- C . Quickspecs
- D . HCL
A customer looks for a storage solution to boot the hypervisor, where one is active and the other standby.
Which solution will allow the requirement?
- A . BIOS
- B . IDSDM
- C . BOSS
- D . UEFI
A server administrator receives reports of high CPU utilization on a Windows server.
Which tool can they use to check for applications that are using excessive amounts of CPU time?
- A . OMSA
- B . Lifecycle Controller
- C . Task Manager
- D . SAE
Refer to the exhibit.

An administrator has a standalone M1000e chassis with only a single CMC module. The CAT6 cable is plugged into the Ethernet port closest to the DB-9 connector. The power indicator light is lit but the administrator is unable to access the CMC module.
What could be the cause of this issue?
- A . No DB-9 serial cable is plugged in
- B . CMC module was removed without powering off the chassis
- C . CAT6 cable into the stacking port
- D . CAT5 cable is required for connection to CMC
What process divides the data into blocks across multiple disk drives?
- A . Parity
- B . Striping
- C . Mirroring
- D . Redundancy
Where are the system settings of a Dell EMC PowerEdge server stored?
- A . CMOS
- B . vFlash
- C . BIOS
- D . UEFI
An administrator sets up an In-Band management method to monitor their Dell EMC PowerEdge servers.
Which protocol uses In-Band management for basic communication and messaging?
- A . SNMP
- B . HTTP
- C . SMTP
- D . FTP